Camere ambientaliRUSSELLS WHD-1152-(4)-40-SCR-A/C
Illinois, Stati UnitiPanoramica
Marca
Modello
Numero id. #
571773
Tipo/Modello
Condizione
Eccellente
Anno
2004
Luogo
Illinois
Stati Uniti
Stati Uniti
Disponibilità
3643142
Dotato
Russells WHD-1152-(4)-40-SCR-A/C Altitude test Chamber ,Interior workspace 144" x144" x96" high, The Altitude control performed up to 100,000 feet with 500 CFM available to the space up to 11,000 ft altitude, built in 2004,
Interior workspace 144" x144" x96"high
The Altitude control performed up to 100,000 feet with 500 CFM available to the space up to 11,000 ft altitude
-30 F to 200 F
10% RH to 95% RH
Needs cooling water, tap water, and compressed air for operationThe system is 173 inches wide and 253 inches deep. The main chamber is 114 inches high with the vacuum system installed on top of that for a total of 210 inche
PERFORMANCE SPECIFICATIONS:
Control Accuracy:
±5% of span
Altitude Range:
Sea level to 100,000 feet minimum
Altitude Performance: (Clean, dry chamber condition)
Sea level to 100,000 feet in 120 minutes
Combined Environments Performance:
The chamber will be capable of simultaneously generating and controlling the following
combinations of environments:
• Steady state or cycling temperature at altitudes to 65,000 feet
• Steady state or cycling temperature/humidity at sea level pressure
• Altitude profiles from sea level to 100,000 feet minimum
electrical power needed 480 volts 3 phase 400 amps
cooling water needed 8 gpm @75 degree F
tap water needed 9.5 gpm @ 30 psi
compressed air bneeded 100 scfm @ 100psi
Spec Sheet
Russells WHD-1152-(4)-40-SCR-A/C Altitude test Chamber ,Interior workspace 144" x144" x96" high, The Altitude control performed up to 100,000 feet with 500 CFM available to the space up to 11,000 ft altitude, built in 2004
Interior workspace 144" x144" x96"high
The Altitude control performed up to 100,000 feet with 500 CFM available to the space up to 11,000 ft altitude
-30 F to 200 F
10% RH to 95% RH
Needs cooling water, tap water, and compressed air for operationThe system is 173 inches wide and 253 inches deep. The main chamber is 114 inches high with the vacuum system installed on top of that for a total of 210 inchesPERFORMANCE SPECIFICATIONS:
Control Accuracy:
±5% of span
Altitude Range:
Sea level to 100,000 feet minimum
Altitude Performance: (Clean, dry chamber condition)
Sea level to 100,000 feet in 120 minutes
Combined Environments Performance:
The chamber will be capable of simultaneously generating and controlling the following
combinations of environments:
• Steady state or cycling temperature at altitudes to 65,000 feet
• Steady state or cycling temperature/humidity at sea level pressure
• Altitude profiles from sea level to 100,000 feet minimum
electrical power needed 480 volts 3 phase 400 amps
cooling water needed 8 gpm @75 degree F
tap water needed 9.5 gpm @ 30 psi